Description
Screw-driven platform lift without shaft
Screw-driven platform lift with ready-made shaft.
Screw-driven platform lift without shaft
Screw-driven platform lift with ready-made shaft.
Screw-driven platform lift with ready-made shaft.
Screw-driven platform lift with ready-made shaft.
Screw-driven cabin lift with sliding doors, available with or without ready-made shaft.
Screw-driven cabin lift with sliding doors, available with or without ready-made shaft.
Screw-driven platform lift with ready-made shaft.
Rated load
3 × 400 VAC & 3 × 230 VAC
900 × 950: 300 kg
900 × 1200: 375 kg
900 × 1400: 450 kg
1100 × 1200: 525 kg
1100 × 1400/1700: 630 kg
1 × 230 VAC
900 × 950: 300 kg
900 × 1200: 375 kg
900 × 1400, 1100 × 1200/ 1400/1700: 385 kg
3 × 400 VAC & 3 × 230 VAC
900 × 950: 300 kg
900 × 1200: 375 kg
900 × 1400: 450 kg
1100 × 1200: 525 kg
1100 × 1400/1700: 630 kg
1 × 230 VAC
900 × 950: 300 kg
900 × 1200: 375 kg
900 × 1400, 1100 × 1200/ 1400/1700: 385 kg
300 kg/3 persons
400 kg/4-5 persons
500 kg/5-6 persons
Lift sizes (w x d, mm)
WITH ready-made shaft
900 x 950
900 x 1200
900 x 1400
1100 x 1200
1100 x 1400
WITHOUT ready-made shaft
900 x 950
900 x 1200
900 x 1400
1100 x 1200
1100 x 1400
1100 x 1700
With ready-made shaft
1100 x 1200
1100 x 1400
Without ready-made shaft
1100 x 1200
1100 x 1400
1100 x 1700
800 x 830
1000 x 830
1000 x 930
1100 x 930
800 x 1217
900 x 1467
1000 x 1267
1000 x 1467
1100 x 1367
1100 x 1467
1100 x 1597
Cut-out sizes, single access (w x d, mm)
Cut-out sizes, straight-through access (w x d, mm)
Door access
Straight-through / Adjacent*
Single access
Straight-through access
Adjacent access
Straight-through / Adjacent*
Single / straight-through / adjacent
Single / straight-through / adjacent
Single / straight-through / adjacent
Single entry
Open-through
Single entry
Open-through
Single entry
Open-through
Adjacent
Door type
Single-hinged doors (all floors)
Single-hinged gate (top floor)
Single-hinged doors (all floors) / single-hinged gate (top floor)
Single-hinged doors (all floors) / single-hinged gate (top floor)
Automatic sliding doors on landings and in cabin
Automatic sliding doors on landings and in cabin
Single-hinged doors (all floors)
Single-hinged gate (top floor)
Power supply
1 x 230 VAC, 50 Hz, 16 A, 3 x 2,5 mm²
3 x 400 VAC, 50 Hz, 16 A, 5 x 2,5 mm²
3 x 230 VAC, 50 Hz, 16 A, 5 x 2,5 mm²
3 x 400 VAC, 50 Hz, 16 A, 5 x 6,0 mm² / 3 x 230 VAC, 50 Hz, 16 A, 5 x 6,0 mm²
1 x 230 VAC, 50 Hz, 16 A, 3 x 2,5 mm² / 3 x 400 VAC, 50 Hz, 16 A, 5 x 2,5 mm² / 3 x 230 VAC, 50 Hz, 16 A, 5 x 2,5 mm²
1 x 230 VAC, 50 Hz, 16 A, 3 x 2,5 mm² / 3 x 400 VAC, 50 Hz, 16 A, 5 x 2,5 mm² / 3 x 230 VAC, 50 Hz, 16 A, 5 x 2,5 mm²
3 x 400 VAC, 50 Hz, 16 A, 5 x 2,5 mm²
3 x 230 VAC, 50 Hz, 16 A, 5 x 2,5 mm²
1 x 230 VAC, 50 Hz, 32 A, 5 x 2,5 mm²
3 x 400 VAC, 50 Hz, 16 A, 5 x 2,5 mm²
3 x 230 VAC, 50 Hz, 16 A, 5 x 2,5 mm²
1 x 230 VAC, 50 Hz, 16 A, 3 x 2,5 mm²
3 x 400 VAC, 50 Hz, 16 A, 5 x 2,5 mm²
3 x 230 VAC, 50 Hz, 16 A, 5 x 2,5 mm²
Standards
Machinery Directive 2006/42/EC
Machinery Directive 2006/42/EC
European Standard EN 81-41
Machinery Directive 2006/42/EC
Machinery Directive 2006/42/EC
Machinery Directive 2006/42/EC, European Standard EN 81-41
Machinery Directive 2006/42/EC, European Standard EN 81-41
Machinery Directive 2006/42/EC
Machinery Directive 2006/42/EC
Machinery Directive 2006/42/EC
European Standard EN 81-41